Product Introduction:
The Yokogawa AAI141-H50 Analog Input Module is a high-performance module designed to provide precise and reliable measurement of analog signals in industrial control systems. As part of the Yokogawa CENTUM VP Distributed Control System (DCS), this module plays a crucial role in monitoring various analog inputs, such as temperature, pressure, flow, and level measurements. The AAI141-H50 is designed to meet the highest standards of industrial automation, ensuring stable performance in demanding environments.
With a focus on flexibility, precision, and reliability, the Yokogawa AAI141-H50 Analog Input Module can be used in a variety of applications across industries such as oil and gas, power, chemical, and process industries. It offers high-speed signal processing, high-accuracy measurements, and robust communication capabilities, making it an essential component for modern automation systems.
Product Parameters:
Feature | Specification |
---|---|
Model | AAI141-H50 |
Input Channels | 8 Analog Input Channels |
Input Type | Voltage, Current, RTD, Thermocouple |
Signal Range (Voltage Input) | 0 to 10 VDC (Nominal) |
Signal Range (Current Input) | 4 to 20 mA (Nominal) |
Accuracy | ±0.1% of Full Scale |
Resolution | 16-bit |
Input Impedance (Voltage) | ≥1 MΩ |
Input Impedance (Current) | ≤250 Ω |
Power Supply | 24 VDC ±20% |
Operating Temperature | -20°C to +60°C |
Mounting | DIN Rail |
Dimensions (L x W x H) | 107.5×32.8×130 mm |
Weight | 0.2 kg |
Response Time | ≤50 ms (Typical) |
Signal Isolation | 1500 Vrms (Between Input and Output) |
Certification | CE, UL, CSA |
Communication Interface | Communication Bus (HART, Modbus) |
Product Applications:
The Yokogawa AAI141-H50 Analog Input Module is versatile and can be employed across various industries and applications where reliable and accurate analog input signal measurement is critical. Some common applications include:
- Oil & Gas: The AAI141-H50 module is used for measuring critical parameters such as pressure, temperature, and flow from field instruments like pressure transmitters, temperature sensors, and flowmeters.
- Power Generation: In power plants, the module helps in monitoring essential signals such as temperature, pressure, and level measurements from boilers, turbines, and cooling systems.
- Chemical & Petrochemical: The module is widely used in the chemical industry for monitoring fluid parameters, enabling precise control over chemical processes and maintaining product quality.
- Water Treatment: Used for continuous monitoring of water quality parameters such as pH, dissolved oxygen, and turbidity in water treatment plants.
- Pharmaceutical: Ensures precise monitoring of process parameters during pharmaceutical manufacturing processes, especially in controlled environments where consistency is key.
- Mining: Used for monitoring parameters in mining operations such as pressure and temperature from safety and process systems.
- Industrial Automation: Essential in factory automation processes for monitoring variables like temperature, humidity, and pressure, ensuring optimal machine operation.
- HVAC Systems: Measures temperature, humidity, and pressure in HVAC systems to maintain environmental conditions.
Product Advantages:
- High Precision and Accuracy: The AAI141-H50 offers ±0.1% accuracy, making it ideal for high-precision measurement applications in industrial environments.
- Wide Input Signal Compatibility: It supports multiple types of input signals, including voltage, current, RTD, and thermocouple, allowing for versatile integration in a wide range of applications.
- Fast Response Time: With a typical response time of ≤50 ms, the module can quickly process analog signals, ensuring real-time control and monitoring.
- High Signal Isolation: The module features 1500 Vrms isolation between input and output, offering excellent protection against electrical noise and surges.
- Flexible Communication: With support for communication protocols such as HART and Modbus, the AAI141-H50 can be easily integrated into existing automation systems.
- Rugged Design: It is designed to operate in harsh industrial environments with a wide operating temperature range of -20°C to +60°C, ensuring reliable performance in diverse conditions.
- Compact and Easy to Install: The module’s compact design allows for efficient use of space and is easy to install with DIN rail mounting.
- Wide Industry Application: It is suitable for a broad range of industries, from power and oil and gas to chemicals and water treatment, making it a versatile component.
- CE, UL, and CSA Certifications: The module meets international safety standards, ensuring compliance with global regulations and enhancing its credibility.
- Robust Signal Processing: With a 16-bit resolution, the AAI141-H50 provides high-quality signal processing, improving measurement accuracy and reliability in control systems.
Latest News Titles:
- “Yokogawa Introduces High-Precision AAI141-H50 Analog Input Module for Industrial Automation”
- “Enhanced Monitoring Capabilities with Yokogawa’s AAI141-H50 Analog Input Module in Chemical Plants”
- “Yokogawa Revolutionizes Power Plant Control with AAI141-H50 Analog Input Module”
- “Yokogawa AAI141-H50 Module: Reliable Analog Measurement for the Oil & Gas Industry”
- “Versatile and Reliable: Yokogawa AAI141-H50 Analog Input Module for Water Treatment Facilities”
- “Pharmaceutical Manufacturing Benefits from Yokogawa AAI141-H50 Analog Input Module”
- “Yokogawa’s AAI141-H50 Enhances Control Systems in Mining Applications”
- “Future-Proof Your Industrial Automation with Yokogawa’s AAI141-H50 Analog Input Module”
- “Streamline Process Control in HVAC Systems with Yokogawa AAI141-H50 Analog Input Module”
- “Yokogawa AAI141-H50 Analog Input Module: Ensuring Optimal Performance in Pharmaceutical Production”
FAQ (Frequently Asked Questions):
-
What types of input signals can the AAI141-H50 handle?
- The module supports voltage, current, RTD, and thermocouple signals, providing flexibility in various measurement applications.
-
What is the accuracy of the AAI141-H50 module?
- The AAI141-H50 offers ±0.1% accuracy, ensuring precise measurements even in demanding environments.
-
What is the response time of the AAI141-H50 module?
- The typical response time is ≤50 ms, enabling real-time monitoring and control.
-
What is the operating temperature range of the AAI141-H50?
- The module operates within a temperature range of -20°C to +60°C, suitable for diverse industrial applications.
-
How many input channels does the AAI141-H50 have?
- The AAI141-H50 features 8 analog input channels for monitoring multiple process variables simultaneously.
-
What is the input impedance for voltage signals on the AAI141-H50?
- The module has an input impedance of ≥1 MΩ for voltage signals.
-
Can the AAI141-H50 be used in hazardous environments?
- Yes, the module is designed for use in industrial environments, and its robust isolation and certifications make it suitable for a wide range of applications.
-
What communication protocols are supported by the AAI141-H50?
- The module supports communication protocols like HART and Modbus, allowing easy integration into existing systems.
-
What is the weight and size of the AAI141-H50 module?
- The module weighs 0.2 kg and has dimensions of 107.5×32.8×130 mm.
-
Does the AAI141-H50 module require a special power supply?
- The AAI141-H50 operates on a 24 VDC ±20% power supply.
Recommended Models:
Model | Specification |
---|---|
Yokogawa AAI141-H51 | 8-Channel Analog Input Module with Enhanced Features |
Yokogawa AAI143-H50 | 16-Channel Analog Input Module |
Yokogawa AAI142-H50 | 8-Channel Voltage and Current Input Module |
Yokogawa AAI144-H50 | 16-Channel RTD and Thermocouple Input Module |
Yokogawa AAI141-H52 | 8-Channel Analog Input Module with Temperature Control |
Yokogawa AAI145-H50 | 4-Channel High-Precision Analog Input Module |
Yokogawa AAI146-H50 | 8-Channel Multifunction Analog Input Module |
Yokogawa AAI147-H50 | 8-Channel Digital-to-Analog Input Module |
Yokogawa AAI148-H50 | 8-Channel Multifunction Input/Output Module |
Yokogawa AAI149-H50 | 8-Channel Analog Input Module with High-Speed Processing |
Popular Models from Yokogawa:
Model | Specification |
---|---|
Yokogawa VSD-H3 | Variable Speed Drive Controller |
Yokogawa DCS C2000 | Distributed Control System |
Yokogawa GA10 | Gas Analyzer |
Yokogawa YTA710 | Temperature Transmitter |
Yokogawa CS3000 | Process Control System |
Yokogawa RTU HMI | Remote Terminal Unit with HMI |
Yokogawa TX200 | High-Accuracy Transmitter |
Yokogawa YFGW710 | Field Wireless Gateway |
Yokogawa SAQ5000 | Signal Analyzing System |
Yokogawa ZR402G | Oxygen Analyzer |