Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666084105 | |||||||
+8613666084105 | ||||||||
13666084105 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The HIMA F3417A 4-Fold Relay Amplifier Module is an advanced component used in safety-critical control and automation systems. This module is a critical part of the HIMA safety portfolio and is designed to offer four independent relay outputs for reliable and safe control in industrial environments. The F3417A module integrates seamlessly into HIMA’s family of safety systems, ensuring compliance with the highest functional safety standards, including SIL 3 (Safety Integrity Level 3) certification.
The F3417A module is typically used in safety-instrumented systems (SIS), emergency shutdown systems (ESD), and other safety-critical applications where precise relay control is essential. It ensures that safety functions are executed accurately and reliably, preventing hazardous situations in critical industries such as oil and gas, chemicals, petrochemicals, power generation, and many others.
This module is designed for use in harsh industrial environments, offering robust construction and the flexibility to meet diverse application requirements. Its compact design, ease of integration, and high reliability make it an ideal choice for modern industrial control systems where safety and uptime are crucial.
Product Specifications
Parameter | Specification |
---|---|
Model | F3417A 4-Fold Relay Amplifier Module |
Type | Relay Amplifier Module |
Channels | 4-Fold (4 Independent Relay Outputs) |
Supply Voltage | 24V DC |
Relay Output Type | Normally Open / Normally Closed |
Operating Temperature | -20°C to +60°C |
Weight | 0.5 kg |
Dimensions (HxWxD) | 120 x 100 x 80 mm |
Mounting | DIN Rail |
Certification | SIL 3 (Safety Integrity Level) |
Power Consumption | 4W |
Housing | ABS (Acrylonitrile Butadiene Styrene) |
Applications
The HIMA F3417A 4-Fold Relay Amplifier Module is ideal for a variety of industrial and safety-critical applications. Some common uses include:
-
Safety Instrumented Systems (SIS): The module is an integral part of systems that monitor and control safety functions to prevent accidents and hazardous situations in high-risk environments.
-
Emergency Shutdown Systems (ESD): The F3417A is used in ESD systems where immediate action is required to shut down critical equipment or processes during an emergency.
-
Fire and Gas Detection Systems: In industries where fire or gas leaks can present significant hazards, the F3417A ensures the timely and reliable activation of alarms and shutdown mechanisms.
-
Industrial Automation: The module is used for controlling machinery, valves, and equipment in automated systems, ensuring safe and efficient operation in complex processes.
-
Process Control in Oil & Gas: The F3417A is employed in high-risk environments such as oil refineries and chemical plants to ensure that the safety functions are reliably executed.
Advantages
-
SIL 3 Certified: The F3417A meets the highest functional safety standards, making it ideal for safety-critical applications in hazardous industries.
-
Four Independent Relays: The module features four separate relay outputs, allowing for versatile and reliable control of multiple safety functions or devices.
-
Wide Temperature Range: With an operating temperature range of -20°C to +60°C, the module is suitable for use in a broad range of industrial environments, from indoor control rooms to harsh outdoor installations.
-
Compact and Flexible: The module’s compact design makes it easy to integrate into existing systems, saving space on DIN rails and ensuring flexibility in system architecture.
-
Energy-Efficient: The F3417A consumes only 4W of power, which helps to reduce operational costs while maintaining high performance.
-
Durability and Reliability: The ABS housing provides durability, ensuring that the module can withstand the rigors of industrial use and maintain reliable operation over time.
-
Ease of Installation: The module is designed for simple DIN rail mounting, enabling quick installation and integration into existing safety systems.
-
Low Maintenance: With its robust design, the F3417A requires minimal maintenance, making it a cost-effective solution in the long term.
Latest News Titles
- “HIMA Expands Safety Portfolio with the Launch of the F3417A 4-Fold Relay Amplifier”
- This article highlights HIMA’s commitment to enhancing safety in industrial control systems with the introduction of the F3417A module.
- “HIMA’s F3417A Module Sets New Standards for SIL 3 Safety Applications”
- A focus on how the F3417A meets stringent SIL 3 certification standards and its role in improving industrial safety.
- “Ensuring Safety in Critical Systems: HIMA’s F3417A Relay Amplifier Module”
- An in-depth exploration of the F3417A module and how it ensures safety and reliability in critical process control applications.
- “HIMA Introduces Advanced Relay Amplifier for Oil and Gas Industry Safety”
- This headline covers the application of the F3417A in the oil and gas industry, where safety is a top priority.
- “New SIL 3 Certified Relay Module from HIMA Improves Control in Safety Systems”
- This article discusses how the F3417A enhances control and reliability in safety systems across various industrial sectors.
FAQ (Frequently Asked Questions)
1.What is the main function of the HIMA F3417A 4-Fold Relay Amplifier Module?
The F3417A is designed to provide four independent relay outputs for safety control in industrial systems, ensuring reliable operation in safety-instrumented systems and emergency shutdown applications.
2.What is the supply voltage required for the F3417A module?
The module operates with a supply voltage of 24V DC.
3.How many relay outputs does the F3417A have?
The module features four independent relay outputs, allowing for versatile control in safety-critical applications.
4.What is the weight of the F3417A module?
The F3417A weighs 0.5 kg.
5.What is the operating temperature range for the F3417A?
The module operates in temperatures ranging from -20°C to +60°C, making it suitable for a wide range of industrial environments.
6.Is the F3417A module certified for functional safety?
Yes, the F3417A is certified for SIL 3, ensuring its compliance with the highest functional safety standards.
7.How is the F3417A module mounted?
The F3417A is mounted on DIN rails, which is a standard method for industrial control and automation equipment.
8.What industries typically use the F3417A module?
The F3417A is used in industries such as oil and gas, chemical processing, power generation, and other safety-critical sectors.
9.How much power does the F3417A consume?
The F3417A module consumes only 4W of power, ensuring energy efficiency while maintaining high reliability.
10.What materials are used in the construction of the F3417A module?
The F3417A is housed in durable ABS plastic, providing protection against harsh industrial environments and ensuring long-term reliability.
Related Models
Model | Description | Application |
---|---|---|
F3305 | Safety Input Module | Safety Instrumented Systems |
F3416 | 2-Fold Relay Amplifier Module | Smaller relay applications in SIS |
F3415 | 4-Fold Relay Module (for simpler systems) | Emergency Shutdown Systems (ESD) |
F3401 | Analog Input Module | Safety process control |
F3418 | 8-Fold Relay Amplifier Module | Large-scale control systems |
F3420 | Relay Output Module | Fire and Gas Detection Systems |
F3470 | Safety Controller | General process automation |
F3430 | Digital Input/Output Module | Integrated control systems |
Popular Models from HIMA
Model | Description | Application |
---|---|---|
F3201 | Safety Controller | Emergency Shutdown Systems (ESD) |
F3300 | Process Safety Module | Industrial process control |
F3500 | Communication Module | Communication between controllers |
F3700 | Signal Conditioning Module | Safety process signal management |
F3600 | I/O Safety Module | Industrial automation and control |
F3800 | Redundant Controller | Critical process control |
F4100 | Analog Output Module | Analog process control |
F5000 | High-speed Digital I/O Module | Fast response safety applications |