Product Introduction
The HIMA F3217 is an advanced 8-channel safety-related input module designed to provide high-level reliability and safety for industrial control systems. This module is part of HIMA’s extensive family of safety systems, offering robust performance for applications that require SIL 3 (Safety Integrity Level 3) certification. It is used primarily in safety-critical environments, such as process automation, emergency shutdown systems (ESD), and other safety-related tasks. The F3217 module ensures that critical safety functions are consistently maintained while meeting strict international standards for industrial safety.
With 8 input channels, this module allows for the connection of a variety of field devices, ensuring that signals are correctly monitored and processed. Its reliability and fault-tolerant design make it an essential part of any high-integrity system, providing comprehensive safety coverage for both small and large-scale automation systems.
Product Specifications
Parameter | Details |
---|---|
Model Number | F3217 |
Type | 8 Channel Safety Related Input Module |
Input Channels | 8 (digital) |
Safety Integrity Level | SIL 3 (Safety Integrity Level 3) |
Nominal Input Voltage | 24 V DC |
Input Type | Digital (Dry Contact / Dry Closure) |
Signal Monitoring | Redundant monitoring for high safety assurance |
Fault Tolerance | 2oo3 (two out of three) voting system |
Temperature Range | -40°C to +70°C (-40°F to +158°F) |
Mounting Type | DIN Rail |
Dimensions (Module) | 200 x 100 x 35 mm |
Weight (Module) | 0.3 kg |
Response Time | < 1 ms |
Power Consumption | 0.7 W (maximum) |
Certifications | SIL 3, IEC 61508, IEC 61511, UL, CE |
Connection Interface | Screw terminal blocks |
Status Indicators | LEDs for each channel (ON/OFF and fault indication) |
Protection | Short-circuit and overload protection |
Product Applications
The HIMA F3217 8 Channel Safety Related Input Module is designed for use in various safety-critical applications, ensuring that safety functions are always operational:
-
Process Control: For monitoring and controlling processes in industries like chemical, oil & gas, and pharmaceuticals.
-
Emergency Shutdown Systems (ESD): Ensures that emergency shutdown signals are safely processed and executed.
-
Fire & Gas Detection: Monitors fire and gas detection systems to initiate appropriate actions if hazardous conditions are detected.
-
Machine Safety: Used in safety systems for monitoring emergency stops, protective doors, and safety light curtains in manufacturing environments.
-
Safety Instrumented Systems (SIS): A key component in safety instrumented systems for providing fail-safe operation.
-
Power Generation: Used for monitoring critical parameters in power plants, ensuring the integrity of safety systems.
Product Advantages
-
High Reliability: The module is designed for high fault tolerance, ensuring that safety functions are not compromised even under challenging conditions.
-
Safety Integrity Level 3 (SIL 3): The F3217 meets the highest safety integrity standards, making it ideal for critical safety applications.
-
Fast Response Time: With a response time of less than 1 ms, the module ensures rapid detection and response to unsafe conditions.
-
Flexible Input Options: The module supports dry contact inputs, offering flexibility in connecting various types of field devices.
-
Robust Environmental Performance: Designed to operate in extreme temperatures ranging from -40°C to +70°C, making it suitable for harsh industrial environments.
-
Easy Installation: The module can be easily mounted on a standard DIN rail, simplifying installation and integration into control panels.
-
Comprehensive Monitoring: Redundant monitoring and fault detection ensure that the system operates at peak reliability.
-
Long-term Durability: Built to last, with protection against short-circuits and overloads to extend the lifespan of both the module and the connected devices.
Frequently Asked Questions (FAQ)
-
What is the primary function of the HIMA F3217 module?
-
It provides 8 digital input channels for safety-related applications, ensuring high reliability and fault tolerance for critical control systems.
-
-
What does SIL 3 certification mean?
-
SIL 3 certification indicates that the module meets the highest safety integrity standards, making it suitable for high-risk applications.
-
-
Can the F3217 module be used in harsh environments?
-
Yes, it operates in a wide temperature range from -40°C to +70°C, making it suitable for a variety of industrial environments.
-
-
What type of inputs does the F3217 support?
-
The module supports dry contact inputs (dry closure), which are common for digital on/off signals from field devices.
-
-
How does the F3217 ensure safety in case of a fault?
-
The module uses a 2oo3 (two out of three) voting system to ensure that a single fault does not compromise safety.
-
-
Is the F3217 easy to integrate into existing systems?
-
Yes, the module can be easily integrated into safety instrumented systems and process control systems, thanks to its standardized DIN rail mounting and simple screw terminal connections.
-
-
What industries can benefit from the F3217 module?
-
The F3217 is ideal for industries such as oil & gas, chemicals, pharmaceuticals, power generation, and manufacturing.
-
-
Does the module offer fault indication?
-
Yes, it has built-in LEDs that indicate the status of each channel, including any faults.
-
-
What certifications does the F3217 module have?
-
It is certified for SIL 3, IEC 61508, IEC 61511, UL, and CE, ensuring compliance with international safety standards.
-
-
What is the power consumption of the F3217 module?
-
The module consumes a maximum of 0.7 W of power during operation.
-
Related Models (Same Series or Functionality)
Model Number | Description |
---|---|
F3227 | 16-channel Safety Input Module with similar safety features |
F3207 | 4-channel Safety Input Module, smaller form factor |
F3210 | 8-channel Input Module with enhanced diagnostics capabilities |
F3237 | 12-channel Safety Input Module for larger-scale systems |
F3247 | 8-channel Input Module with integrated relay outputs |
F3267 | High-density input module with extended fault tolerance |
Popular Models from HIMA (Other Categories)
Model Number | Type | Description |
---|---|---|
F2130 | Safety Related Output Module | Output module for controlling safety-critical actuators |
F3000 | Safety Controller Module | Centralized safety controller for various safety systems |
F2132 | 2-channel Safety Output Module | Compact output module for small safety systems |
F3100 | Safety I/O Module | Modular I/O system for safety applications |
F3120 | Safety Interface Module | Interfaces external devices with the safety controller |
F3140 | Advanced Safety Controller | High-performance controller for large-scale safety systems |